The ResMed Airsense 11 is a well-liked CPAP machine that provides quite a lot of options to make sleep apnea remedy extra snug and efficient. One among these options is the auto humidity setting, which robotically adjusts the humidity stage of the air you breathe to assist cut back dryness and irritation. In case you’re unsure the way to activate the auto humidity setting, comply with these easy steps.

First, be sure that your Airsense 11 is turned on. Then, press the “Settings” button on the entrance of the machine. From the Settings menu, choose the “Humidification” tab. On the Humidification tab, you will note an possibility for “Auto Humidity.” Merely choose this selection and press the “OK” button. The Airsense 11 will now robotically regulate the humidity stage of the air you breathe based mostly on the ambient temperature and humidity.

Utilizing the auto humidity setting will help to cut back dryness and irritation, which may make CPAP remedy extra snug. It may additionally assist to enhance the effectiveness of your CPAP remedy by decreasing the quantity of air leakage that happens. In case you’re unsure whether or not the auto humidity setting is best for you, speak to your physician. They will help you identify one of the best settings on your particular person wants.

Enabling Auto Humidity on Your AirSense 11 Gadget

To take pleasure in the advantages of computerized humidity management along with your ResMed AirSense 11 gadget, comply with these easy steps:

1. Entry the Medical Menu

A. Energy in your AirSense 11 gadget.
B. Press the Residence button.
C. Scroll down and choose the “Medical” possibility utilizing the navigation wheel.
D. Enter the Medical Menu password. The default password is “4191.”
E. Navigate to the “Humidifier” tab utilizing the navigation wheel.
F. Scroll right down to the “Humidity Management Mode” possibility.
G. Choose “Auto” utilizing the navigation wheel.

Extra Directions for Detailed Setup:

Choice Description
Set Fastened Stage Alter the humidity stage manually utilizing the navigation wheel.
Heated Tube Solely Disable humidification, leaving solely the heated tube to heat the air.
Auto Allow computerized humidity management, with the gadget adjusting the humidity stage based mostly in your respiratory patterns and ambient situations.

Navigating the MyAir App or Gadget Interface

Accessing the MyAir App

To entry the MyAir app, you possibly can obtain it from the App Retailer (for iOS gadgets) or Google Play (for Android gadgets). As soon as put in, launch the app and create an account in case you do not have already got one. Check in to your account and join your Airsense 11 gadget by way of Bluetooth.

Gadget Interface

In case you choose to navigate the settings from the gadget itself, you’ll find the auto humidity possibility within the Gadget Settings menu. Use the navigation buttons on the gadget to scroll by the choices till you discover “Gadget Settings.” Choose this selection and press the OK button. Inside the Gadget Settings menu, navigate to the “Humidity” setting and use the navigation buttons to toggle between the out there humidity choices, together with “Auto.” Press the OK button to verify your choice.

Auto Humidity Setting

When you choose the auto humidity setting, the gadget will robotically regulate the humidity stage based mostly on a number of components, such because the ambient temperature, room temperature, and your respiratory patterns. This setting goals to offer optimum consolation by stopping each dry mouth and extreme humidity within the masks.

Auto Humidity Setting
Adjusts humidity stage based mostly on ambient temperature, room temperature, and respiratory patterns
Prevents dry mouth and extreme humidity
Offers optimum consolation

Choosing the Humidity Stage

After choosing the “Auto Humidity” setting, you have to select the specified humidity stage. The CPAP gadget will preserve the humidity at this stage, offering a extra snug remedy expertise. Listed here are the steps concerned:

1. Entry the Menu

With the CPAP gadget is powered on, press the “Menu” button on the management panel. Navigate by the menu choices utilizing the arrow buttons.

2. Discover Humidity Settings

Find the “Humidity Settings” or “Moisture Settings” possibility within the menu. Use the arrow buttons to scroll to this setting.

3. Set the Humidity Stage

Relying in your preferences and the CPAP mannequin, you could have varied humidity stage choices to select from. Widespread humidity ranges vary from 0% to heated, or absolutely humidified. You’ve gotten the pliability to regulate the humidity stage to fit your consolation and desires.

This is a desk summarizing the humidity stage choices out there on widespread CPAP fashions:

CPAP Mannequin Humidity Stage Choices
ResMed Airsense 11 0%, 1-8, Auto, Heated
Philips DreamStation 2 Off, 1-5, Auto, Heated
Breeze Freedom 0%, 1-8, AutoSet, Heated

Customizing Humidity Settings

The Airsense 11 means that you can customise the humidity stage to fit your consolation preferences. This is the way to regulate the settings:

1. Enter the Menu

Press the “Menu” button on the gadget.

2. Navigate to “Settings”

Use the navigation buttons to scroll down and choose “Settings.” Press the “OK” button to enter.

3. Select “Humidifier”

From the Settings menu, scroll down and choose “Humidifier.” Press the “OK” button to entry the humidifier settings.

4. Set the Humidity Stage

The Airsense 11 affords three humidity ranges:

Stage Description
Auto Routinely adjusts the humidity stage based mostly on the ambient temperature and humidity. That is the really useful setting for many customers.
Fastened Maintains a continuing humidity stage whatever the ambient situations. You may manually regulate the humidity stage from 1 to eight.
Off Turns off the humidifier.

To set the humidity stage, choose the specified possibility and press the “OK” button.

Understanding the Advantages of Auto Humidity

Auto humidity adjusts the humidity stage within the humidifier chamber based mostly on the ambient temperature and the person’s respiratory patterns. This gives a number of benefits:

  • Optimum Consolation: Auto humidity maintains a snug humidity stage, stopping dryness or over-humidification, which may result in discomfort or irritation.
  • Improved Sleep High quality: A correctly humidified atmosphere promotes restful sleep by decreasing congestion and dryness, which may disrupt sleep patterns.
  • Lowered Condensation: Auto humidity helps decrease condensation on the masks and tubing, bettering the general person expertise and decreasing the danger of masks leaks.
  • Enhanced Remedy: Optimum humidity ranges can improve the effectiveness of CPAP remedy by decreasing airway resistance and bettering fuel alternate.

5. Customized Humidity Management

Auto humidity affords personalised humidity management. The gadget analyzes the person’s respiratory patterns and ambient temperature to find out the optimum humidity stage. This stage may be additional adjusted inside a variety to go well with particular person preferences. The exact humidity management enhances the person’s consolation and ensures that the humidifier gives the specified stage of humidification.

Temperature Vary (°C) Relative Humidity Vary (%)
10–20 30–45
20–25 35–50
25–30 40–55

The desk signifies the really useful relative humidity vary for various ambient temperature ranges. Auto humidity robotically adjusts inside these ranges to keep up optimum consolation and remedy effectiveness.

Sustaining Optimum Consolation Ranges

Utilizing a CPAP machine may be an efficient approach to enhance your sleep and general well being. Nonetheless, if the settings usually are not adjusted appropriately, it could possibly result in discomfort and even exacerbate your sleep issues.

One of the crucial vital settings to regulate is the humidity stage. The perfect humidity stage will differ from individual to individual, however it’s typically really useful to set it between 30% and 60%. If the humidity stage is just too low, it could possibly trigger your nostril and throat to grow to be dry and irritated. This could result in discomfort and even make it tougher to breathe.

If the humidity stage is just too excessive, it could possibly trigger condensation to construct up within the masks. This could make the masks uncomfortable to put on and may result in pores and skin irritation.

Adjusting the Humidity Setting

To regulate the humidity setting in your Airsense 11 CPAP machine, comply with these steps:

1. Press the “Menu” button on the entrance of the machine.
2. Use the arrow keys to navigate to the “Local weather Management” menu.
3. Press the “Enter” button.
4. Use the arrow keys to navigate to the “Humidity Stage” setting.
5. Press the “Enter” button.
6. Use the arrow keys to regulate the humidity stage to the specified setting.
7. Press the “Enter” button to avoid wasting the setting.

Ideas for Selecting the Proper Humidity Setting

The next suggestions will help you select the precise humidity setting on your CPAP machine:

  • Begin with the bottom humidity setting and steadily improve it till you discover a setting that’s snug for you.
  • In case you expertise dry nostril or throat, strive growing the humidity stage.
  • In case you expertise condensation within the masks, strive lowering the humidity stage.
  • Totally different climates might require totally different humidity settings. For instance, you might want to make use of the next humidity setting in a dry local weather than in a damp local weather.

You probably have any questions or issues concerning the humidity setting in your CPAP machine, make sure to seek the advice of along with your physician or sleep therapist.

Troubleshooting Humidity Points

Understanding Humidity Settings

The Airsense 11 humidifier contains three humidity settings: No Humidity, Fastened Humidity, and Auto Humidity. Auto Humidity robotically adjusts the humidity stage based mostly on the ambient temperature and airflow.

Adjusting Humidity Stage in Auto Mode

To allow Auto Humidity, entry the humidifier settings menu in your CPAP machine. The machine will robotically regulate the humidity stage, offering a snug and efficient respiratory expertise.

Resolving Auto Humidity Issues

In case you expertise points with Auto Humidity, think about the next troubleshooting steps:

1. Checking the Water Tank: Make sure the water tank is stuffed and correctly put in. An empty tank will forestall humidification.

2. Inspecting the Humidifier Chamber: Take away the humidifier chamber and examine it for any leaks or obstructions. Clear or exchange the chamber if needed.

3. Resetting the CPAP Machine: Flip off the machine, unplug it for a couple of seconds, after which plug it again in. This will likely resolve any software program glitches.

4. Adjusting the Room Temperature: Auto Humidity works greatest in rooms with temperatures between 60-80°F (15-27°C). If the room is just too chilly or scorching, it might have an effect on humidity ranges.

5. Checking the Local weather Management System: Make sure the humidifier isn’t competing with different moisture-producing home equipment reminiscent of a humidifier or dehumidifier.

6. Inspecting the Air Filter: A unclean air filter can limit airflow and affect humidity ranges. Clear or exchange the filter as wanted.

7. Contacting the Producer: If not one of the above steps resolve the difficulty, contact the producer of your CPAP machine for additional help or alternative elements.

Error Code Doable Trigger Resolution
E-10 Communication Error Reset the gadget by unplugging and plugging it again in. If the error persists, contact the producer.

Using the On-Board Humidifier

The AirSense 11 AutoSet may be outfitted with a built-in humidifier to offer supplemental moisture to the remedy air. This will help alleviate dryness within the nostril, throat, and sinuses, particularly throughout chilly or dry seasons. This is the way to activate and use the on-board humidifier:

1. Make sure that the humidifier is full of distilled water as much as the utmost fill line.

2. Join the humidifier to the AirSense 11 gadget and activate the machine.

3. Press the “Humid” button on the LCD display screen to allow the humidifier.

4. Use the arrow keys to regulate the humidity stage from 0 (off) to eight (max).

5. Monitor the humidity indicator on the LCD display screen to make sure it is inside your required consolation stage.

6. To show off the humidifier, press the “Humid” button once more or set the humidity stage to 0.

7. Repeatedly examine the humidifier water stage and refill it as wanted to keep up optimum efficiency.

8. For superior settings, reminiscent of computerized humidity adjustment based mostly on ambient temperature and altitude, seek the advice of the gadget handbook or check with the desk beneath:

Setting Description
Auto Adjusts humidity robotically based mostly on ambient temperature and altitude.
Fastened Maintains a continuing humidity stage no matter environmental situations.
Off Disables the humidifier.

Guaranteeing Correct Gadget Setup

To make sure one of the best efficiency out of your AirSense 11 gadget, it is essential to set it up appropriately. This is a step-by-step information to make sure correct setup:

1. Unpack the Gadget and Equipment

Take away the gadget and equipment from the packaging and examine them for any injury.

2. Connect the HumidAir Tubing

Join the blue HumidAir tubing to the HumidAir outlet on the again of the gadget.

3. Connect the HumidAir Humidifier

Insert the HumidAir humidifier into the HumidAir tubing and switch it clockwise to safe it.

4. Fill the HumidAir Humidifier

Take away the water tank from the humidifier and fill it with distilled or purified water. Reattach the water tank.

5. Connect the Masks to the Tubing

Join the masks to the alternative finish of the HumidAir tubing.

6. Alter the Masks

Placed on the masks and regulate the straps to make sure a snug match. Keep away from overtightening the straps.

7. Energy On the Gadget

Plug the gadget into an influence outlet and press the ability button.

8. Set the Auto Humidity Setting

Navigate to the “My Choices” menu on the gadget display screen and choose “Humidity Settings.” Select “Auto” to allow the auto humidity setting.

9. Detailed Rationalization of Humidity Settings

The AirSense 11 affords three humidity settings:

Setting Description
Fastened Maintains a continuing humidity stage all through the night time.
Auto Routinely adjusts humidity based mostly on room temperature and respiratory patterns.
Off Disables humidification.

For many customers, the “Auto” setting is really useful because it gives personalised humidification ranges that adapt to altering situations.

Optimizing Sleep High quality with Auto Humidity

What’s Auto Humidity?

Auto Humidity is a function of the Airsense 11 CPAP machine that robotically adjusts the humidity stage based mostly on the person’s respiratory patterns and the ambient atmosphere. This gives optimum consolation and therapeutic advantages all through the night time.

Advantages of Auto Humidity

  1. Lowered nasal dryness and congestion
  2. Improved sleep high quality
  3. Lowered rainout
  4. Enhanced adherence to CPAP remedy

How one can Activate Auto Humidity

  1. Entry the Medical Menu in your Airsense 11 gadget.
  2. Scroll right down to “Humidification.”
  3. Choose “Auto Humidity.”
  4. Select the specified humidity stage vary (Really useful: 4-8).
  5. Affirm your settings.

Superior Auto Humidity Settings

For optimum customization, the Airsense 11 affords superior Auto Humidity settings. These embody:

Setting Description
Auto Humidity Response Adjusts the humidity response time based mostly on respiratory patterns.
Adaptive Humidification Learns and adapts to the person’s respiratory patterns over time.
Heated Tube Temperature Controls the temperature of the heated tube to cut back rainout.

Extra Ideas

  • Use distilled water within the humidifier chamber to forestall mineral buildup.
  • Clear the humidifier chamber and water tub recurrently to keep up hygiene.
  • In case you expertise extreme rainout, regulate the heated tube temperature or seek the advice of your healthcare supplier.

Conclusion

Auto Humidity is a beneficial function that may considerably improve the consolation and effectiveness of CPAP remedy. By robotically adjusting humidity ranges, the Airsense 11 CPAP machine gives optimum sleep situations, decreasing nasal dryness, bettering sleep high quality, and selling adherence to remedy.

How To Flip Airsense 11 To Auto Humidity Setting

The AirSense 11 is a well-liked CPAP machine that provides quite a lot of options to make it snug to make use of. One among these options is the flexibility to robotically regulate the humidity stage of the air that’s delivered to the person. This may be useful for individuals who expertise dry mouth or nasal congestion throughout CPAP remedy.

To activate the Auto Humidity setting, first, be sure that the humidifier is hooked up to the CPAP machine. Then, press the Menu button on the entrance of the machine. Use the arrow keys to navigate to the Humidification menu and press the Choose button. Then, use the arrow keys to navigate to the Auto Humidity setting and press the Choose button. The machine will now robotically regulate the humidity stage based mostly on the person’s respiratory patterns.

The Auto Humidity setting could be a useful approach to enhance the consolation of CPAP remedy. Nonetheless, it is very important word that this setting might not be appropriate for everybody. Individuals who have a historical past of respiratory issues ought to speak to their physician earlier than utilizing the Auto Humidity setting.

Individuals Additionally Ask

How do I flip off the Auto Humidity setting on the AirSense 11?

To show off the Auto Humidity setting, comply with the identical steps as above however choose the Off possibility as a substitute of the Auto Humidity possibility.

What’s the greatest humidity setting for CPAP?

The perfect humidity setting for CPAP will differ from individual to individual. Some folks discover {that a} decrease humidity setting is extra snug, whereas others choose the next humidity setting. You will need to experiment with totally different settings to seek out what works greatest for you.

Can I exploit the AirSense 11 with out the humidifier?

Sure, you should utilize the AirSense 11 with out the humidifier. Nonetheless, it is very important word that this will make the remedy much less snug. In case you expertise dry mouth or nasal congestion, you might need to strive utilizing the humidifier.