5 Steps: How to Graph 2nd Order LTI on Bode Plot

5 Steps: How to Graph 2nd Order LTI on Bode Plot

Understanding the intricacies of second-order linear time-invariant (LTI) methods is essential in numerous engineering disciplines. Bode plots, a graphical illustration of a system’s frequency response, supply a complete evaluation of those methods, enabling engineers to visualise their habits and make knowledgeable design selections.

On this context, graphing second-order LTI methods on Bode plots is a vital talent. It permits engineers to check the system’s magnitude and part response over a variety of frequencies, offering precious insights into the system’s stability, bandwidth, and damping traits. By using the rules of Bode evaluation, engineers can acquire a deeper understanding of how these methods behave in numerous frequency regimes and make vital changes to optimize efficiency.

To successfully graph second-order LTI methods on Bode plots, it is very important first perceive the underlying mathematical equations governing their habits. These equations describe the system’s switch perform, which in flip determines its frequency response. By making use of logarithmic scales to each the frequency and amplitude axes, Bode plots present a handy technique to visualize the system’s habits over a variety of frequencies. By rigorously analyzing the ensuing plots, engineers can establish key options equivalent to cutoff frequencies, resonant peaks, and part shifts, and use this data to design methods that meet particular efficiency necessities.

Introduction to Bode Plots

Bode plots are graphical representations of the frequency response of a system. They’re used to research the soundness, bandwidth, and resonance of a system. Bode plots can be utilized to design filters, amplifiers, and different digital circuits.

The frequency response of a system is the output of the system as a perform of the enter frequency. The Bode plot is a plot of the magnitude and part of the frequency response on a logarithmic scale.

The magnitude of the frequency response is often plotted in decibels (dB). The decibel is a logarithmic unit of measurement that’s used to specific the ratio of two energy ranges. The part of the frequency response is often plotted in levels.

Bode plots can be utilized to find out the next traits of a system:

  • Stability: The steadiness of a system is set by the part margin of the system. The part margin is the distinction between the part of the system on the crossover frequency and 180 levels. A steady system has a part margin of no less than 45 levels.
  • Bandwidth: The bandwidth of a system is the frequency vary over which the system has a acquire of no less than 3 dB.
  • Resonance: The resonance frequency of a system is the frequency at which the system has a peak acquire.

2nd Order Linear Time-Invariant Techniques

A 2nd order linear time-invariant (LTI) system is a system that’s described by the next differential equation:

y'' + 2ζωny' + ωny^2 = Ku

the place:

  • y is the output of the system
  • u is the enter to the system
  • ζ is the damping ratio
  • ωn is the pure frequency
  • Ok is the acquire

The damping ratio and pure frequency are two vital parameters that decide the habits of a 2nd order LTI system. The damping ratio determines the quantity of damping within the system, whereas the pure frequency determines the frequency at which the system oscillates.

The next desk exhibits the various kinds of 2nd order LTI methods, relying on the values of the damping ratio and pure frequency:

Damping Ratio Pure Frequency Kind of System
ζ > 1 Any Overdamped
ζ = 1 Any Critically damped
0 < ζ < 1 Any Underdamped
ζ = 0 ωn = 0 Marginally steady
ζ = 0 ωn ≠ 0 Unstable

Bode plots can be utilized to research the frequency response of 2nd order LTI methods. The form of the Bode plot is dependent upon the damping ratio and pure frequency of the system.

Switch Operate of a 2nd Order LTI System

A second-order linear time-invariant (LTI) system is described by a switch perform of the shape:

“`
H(s) = Ok / ((s + a)(s + b))
“`

the place:
– Ok is the system acquire
– a and b are the poles of the system (the values of s for which the denominator of H(s) is zero)
– s is the Laplace variable

The poles of a system decide its response to an enter sign. A system with complicated poles may have an oscillatory response, whereas a system with actual poles may have an exponential response.

The next desk summarizes the traits of second-order LTI methods with totally different pole areas:

Pole Location Response
Actual and distinct Two exponential decays
Actual and equal One exponential decay
Advanced Oscillatory decay

The Bode plot of a second-order LTI system is a plot of the system’s magnitude and part response as a perform of frequency.

Asymptotic Habits Evaluation of the Bode Plot

1. Excessive-Frequency Asymptotes

At excessive frequencies, the Bode plot displays predictable asymptotic habits. For phrases with optimistic exponents, the asymptote follows the slope of that exponent. For instance, a time period with an exponent of +2 produces an asymptote with a +2 slope (12 dB/octave). Conversely, phrases with detrimental exponents create asymptotes with detrimental slopes. A time period with an exponent of -1 generates an asymptote with a -1 slope (6 dB/octave).

2. Low-Frequency Asymptotes

Within the low-frequency area, the Bode plot’s asymptotes rely upon the fixed time period. If the fixed time period is optimistic, the asymptote stays at 0 dB. Whether it is detrimental, the asymptote has a detrimental slope equal to the fixed’s exponent. For example, a relentless time period of -2 produces an asymptote with a -2 slope (12 dB/octave).

3. Mixed Asymptotic Habits Evaluation

The asymptotic habits of a switch perform is usually a complicated interaction of a number of phrases. To investigate it successfully, comply with these steps:

  1. Establish particular person asymptotic behaviors: Decide the high- and low-frequency asymptotes of every time period within the switch perform.
  2. Superimpose asymptotes: Overlap the person asymptotes to create a composite asymptotic profile. This profile outlines the general form of the Bode plot.
  3. Breakpoints: Establish the frequencies the place asymptotes change slope. These breakpoints point out the place the switch perform’s dominant phrases swap.
  4. Mid-Frequency Area: Analyze the habits between the breakpoints to find out any deviations from the asymptotic strains.
Time period Excessive-Frequency Asymptote Low-Frequency Asymptote
s + 2 +1 (20 dB/decade) 0 dB
s – 1 0 dB -1 (20 dB/decade)
1/(s2 + 1) -2 (40 dB/decade) 0 dB

Figuring out the Nook Frequencies

The nook frequencies are the frequencies at which the system’s response modifications from one kind of habits to a different. For a second-order LTI system, there are two nook frequencies: the pure frequency (ωn) and the damping ratio (ζ).

The Pure Frequency

The pure frequency is the frequency at which the system would oscillate if there have been no damping. It’s decided by the system’s mass and stiffness.

The pure frequency could be discovered utilizing the next system:

$$omega_n = sqrt{frac{okay}{m}}$$
the place:
* ωn is the pure frequency in radians per second
* okay is the spring fixed in newtons per meter
* m is the mass in kilograms

The Damping Ratio

The damping ratio is a measure of how shortly the system’s oscillations decay. It ranges from 0 to 1. A damping ratio of 0 signifies that the system will oscillate indefinitely, whereas a damping ratio of 1 signifies that the system will return to its equilibrium place shortly with out overshooting.

The damping ratio could be discovered utilizing the next system:

$$zeta = frac{c}{2sqrt{km}}$$
the place:
* ζ is the damping ratio
* c is the damping coefficient in newtons-seconds per meter
* okay is the spring fixed in newtons per meter
* m is the mass in kilograms

Establishing the Magnitude Plot

The magnitude plot exhibits the acquire in decibels (dB) as a perform of the frequency. To assemble the magnitude plot, comply with these steps:

1. **Discover the cutoff frequency (ωc)**: That is the frequency at which the acquire is down by 3 dB from the DC acquire.

2. **Discover the slope:** The slope of the magnitude plot is -20 dB/decade for a first-order system and -40 dB/decade for a second-order system.

3. **Draw the asymptotes:** Draw two asymptotes, one with the slope present in step 2 and one with a acquire of 0 dB.

4. **Interpolate the asymptotes to seek out the magnitude on the specified frequencies**:

  1. Discover the acquire in dB on the cutoff frequency from the asymptotes.
  2. Discover the frequency at which the acquire is 20 dB under the DC acquire.
  3. Discover the frequency at which the acquire is 40 dB under the DC acquire (for second-order methods solely).
  4. Draw a line connecting these factors to approximate the magnitude plot.

5. **Plot the magnitude response:** Plot the acquire in dB on the vertical axis and the frequency on the horizontal axis. The ensuing plot is the magnitude plot of the 2nd order LTI system.

The next desk summarizes the steps for setting up the magnitude plot:

Step Motion
1 Discover the cutoff frequency
2 Discover the slope
3 Draw the asymptotes
4 Interpolate the asymptotes
5 Plot the magnitude response

Plotting the Section Plot

The part plot supplies details about the part shift of the output sign relative to the enter sign. To plot the part plot, comply with these steps:

  1. Plot the imaginary a part of the switch perform, (Im(H(jomega))), on the vertical axis.
  2. Plot the true a part of the switch perform, (Re(H(jomega))), on the horizontal axis.
  3. The ensuing curve is the part plot.

The part plot is often represented as a graph of part shift (in levels) versus frequency ($omega$). The part shift is calculated utilizing the system:
“`
Section Shift = arctan(Im(H(jomega))/Re(H(jomega)))
“`

The part plot can be utilized to find out the soundness and part margin of the system. A detrimental part shift signifies that the output sign is lagging the enter sign, whereas a optimistic part shift signifies that the output sign is main the enter sign.

The next desk exhibits the connection between the part shift and the soundness of the system:

Section Shift Stability
Steady
-90° to 0° Marginally steady
-90° to -180° Unstable

The part margin is the distinction between the part shift on the crossover frequency (the place the magnitude of the switch perform is 0 dB) and -180°. A part margin of no less than 45° is mostly thought of to be acceptable for stability.

Slopes and Breakpoints within the Bode Plot

Slope of the Bode Plot

The slope of the Bode plot signifies the speed of change within the magnitude or part response of a system with respect to frequency. A optimistic slope signifies a rise in magnitude or part with rising frequency, whereas a detrimental slope signifies a lower. The slope of the Bode plot could be decided by the order of the system and the kind of filter it’s. For instance, a first-order low-pass filter may have a slope of -20 dB/decade within the magnitude plot and -90 levels/decade within the part plot.

Breakpoints of the Bode Plot

The breakpoints of the Bode plot are the frequencies at which the slope of the plot modifications. These breakpoints happen on the pure frequencies of the system, that are the frequencies at which the system oscillates when it’s excited by an impulse. The breakpoints of the Bode plot can be utilized to find out the resonant frequencies and damping ratios of the system.

Magnitude and Section Breakpoints of 2nd Order LTI System

Magnitude Breakpoint Section Breakpoint
$omega_n$ $0.707 omega_n$

$omega_n sqrt{1+2zeta^2}$ $omega_n$

$omega_n sqrt{1-2zeta^2}$ $omega_n sqrt{1-2zeta^2}$

Overdamped Circumstances

Within the overdamped case, the system’s response to a step enter is sluggish and gradual, with none oscillations. This happens when the damping ratio (ζ) is bigger than 1. The Bode plot for an overdamped system has the next traits:

  • The magnitude response (20 log|H(f)|) is a horizontal line at -6 dB/octave, indicating a roll-off of 6 dB per octave.
  • The part response is a straight line with a slope of -90 levels/decade, indicating a part lag of 90 levels in any respect frequencies.

Underdamped Circumstances

Within the underdamped case, the system’s response to a step enter is oscillatory, with the oscillations steadily lowering in amplitude over time. This happens when the damping ratio (ζ) is lower than 1. The Bode plot for an underdamped system has the next traits:

  • The magnitude response has a peak on the resonant frequency (ωn), with the height magnitude relying on the damping ratio.
  • The part response begins at -90 levels at low frequencies and approaches -180 levels at excessive frequencies, passing by -135 levels on the resonant frequency.

Critically Damped Circumstances

Within the critically damped case, the system’s response to a step enter is the quickest potential with none oscillations. This happens when the damping ratio (ζ) is the same as 1. The Bode plot for a critically damped system has the next traits:

  • The magnitude response is a horizontal line at -6 dB/octave, indicating a roll-off of 6 dB per octave.
  • The part response is a straight line with a slope of -180 levels/decade, indicating a part lag of 180 levels in any respect frequencies.

Bode Plot Traits for Totally different Damping Circumstances

Damping Case Magnitude Response Section Response
Overdamped (ζ > 1) -6 dB/octave -90 levels/decade
Underdamped (ζ < 1) Peak at resonant frequency (ωn) -90 levels at low frequencies, -180 levels at excessive frequencies
Critically Damped (ζ = 1) -6 dB/octave -180 levels/decade

Impression of Pole and Zero Areas on the Bode Plot

Poles and Zeros at Origin

A pole on the origin provides a -20 dB/decade slope within the magnitude response. A zero on the origin will give a +20 dB/decade slope.

Poles and Zeros at Infinity

A pole at infinity has no impact on the magnitude response. A zero at infinity provides a -20 dB/decade slope.

Poles and Zeros on Actual Axis

A pole on the true axis provides a -20 dB/decade slope with a nook frequency equal to absolutely the worth of the pole location. A zero on the true axis provides a +20 dB/decade slope, additionally with a nook frequency equal to absolutely the worth of the zero location.

Poles and Zeros on Imaginary Axis

A pole on the imaginary axis provides a -90 diploma part shift. A zero on the imaginary axis provides a +90 diploma part shift. The nook frequency is the same as the imaginary a part of the pole or zero location.

Poles within the Left Half Aircraft (LHP)

Poles within the LHP contribute to the soundness of the system. They provide a -20 dB/decade slope within the magnitude response and a -90 diploma part shift. The nook frequency is the same as the gap from the pole location to the imaginary axis.

Zeros within the Left Half Aircraft (LHP)

Zeros within the LHP don’t contribute to the soundness of the system. They provide a +20 dB/decade slope within the magnitude response and a +90 diploma part shift. The nook frequency is the same as the gap from the zero location to the imaginary axis.

Advanced Poles and Zeros

Advanced poles and zeros give a mixture of the above results. The magnitude response may have a slope that may be a mixture of -20 dB/decade and +20 dB/decade, and the part response may have a mixture of -90 diploma shift and +90 diploma shift. The nook frequency is the same as the gap from the pole or zero location to the origin.

Pole-Zero Cancellations

If a pole and a zero are positioned on the similar frequency, they’ll cancel one another out. This may lead to a flat (zero slope) magnitude response and a linear part response within the frequency vary across the cancellation frequency.

Pole or Zero Location Magnitude Slope Section Shift Nook Frequency
Origin -20 dB/decade 0
Infinity 0 -20 dB/decade
Actual Axis (optimistic) -20 dB/decade -90 Pole location
Actual Axis (detrimental) -20 dB/decade -90 -Pole location
Imaginary Axis (optimistic) 0 +90 Zero location
Imaginary Axis (detrimental) 0 -90 -Zero location
Left Half Aircraft (LHP) -20 dB/decade -Section angle Distance to imaginary axis
Proper Half Aircraft (RHP) +20 dB/decade +Section angle Distance to imaginary axis
Advanced Aircraft Mixture of above Mixture of above Distance to origin
Pole-Zero Cancellation 0 Linear Cancellation frequency

Acquire and Section Margin Calculations

Bode plots are indispensable for calculating acquire and part margins, which decide the soundness and robustness of a management system. Acquire margin measures the quantity by which the system’s acquire could be elevated earlier than instability happens, whereas part margin measures the quantity by which the system’s part could be elevated earlier than instability arises. Bode plots present a simple methodology for figuring out these margins, guaranteeing management system stability.

Loop Shaping for Management System Design

Utilizing Bode plots, management engineers can form the frequency response of a management loop to attain desired efficiency traits. By adjusting the acquire and part of the system at particular frequencies, they’ll optimize the loop’s stability, bandwidth, and disturbance rejection capabilities, guaranteeing optimum system operation.

Stability Evaluation of Techniques with A number of Inputs and Outputs

Bode plots are notably helpful for analyzing the soundness of MIMO (A number of-Enter A number of-Output) methods, the place interactions between a number of inputs and a number of outputs can complicate stability evaluation. By setting up Bode plots for every input-output pair, engineers can establish potential stability points and design management methods to make sure system robustness.

Compensation Design for Suggestions Management Loops

Bode plots present a precious device for designing compensation networks to enhance the efficiency of suggestions management loops. By including lead or lag compensators, engineers can modify the system’s frequency response to boost stability, cut back steady-state errors, and enhance dynamic efficiency.

Evaluation of Closed-Loop Techniques

Bode plots are important for analyzing the closed-loop habits of management methods. They permit engineers to foretell the system’s output response to exterior disturbances and decide system parameters equivalent to rise time, settling time, and frequency response.

Predictive Management and Mannequin-Primarily based Design

Bode plots are more and more utilized in predictive management and model-based design approaches, the place system fashions are developed and used for management. By evaluating the precise Bode plots with the anticipated ones, engineers can validate fashions and design management methods that meet efficiency specs.

The best way to Graph 2nd Order LTI on Bode Plot

A second-order linear time-invariant (LTI) system could be represented by the next switch perform:

“`
H(s) = Ok * (s + z1) / (s^2 + 2*zeta*wn*s + wn^2)
“`

the place Ok is the acquire, z1 is the zero, wn is the pure frequency, and zeta is the damping ratio.

To graph the Bode plot of a 2nd order LTI system, comply with these steps:

  1. Calculate the acquire, zero, pure frequency, and damping ratio of the system.
  2. Create a Bode plot template with frequency on the x-axis and magnitude and part on the y-axis.
  3. Plot the acquire as a horizontal line at 20*log10(Ok) dB.
  4. For the magnitude plot, plot a curve with a slope of -20 dB/decade for frequencies under wn and a slope of -40 dB/decade for frequencies above wn.
  5. For the part plot, plot a curve with a slope of -90 levels/decade for frequencies under wn and a slope of -180 levels/decade for frequencies above wn.
  6. Regulate the magnitude and part curves based mostly on the zero and damping ratio of the system.

Individuals Additionally Ask

What’s a Bode plot?

A Bode plot is a graphical illustration of the frequency response of a system. It exhibits the magnitude and part of the system’s switch perform at totally different frequencies.

What’s the goal of a Bode plot?

Bode plots are used to research the soundness and efficiency of methods. They can be utilized to find out the system’s acquire, bandwidth, and part margin.

How do I learn a Bode plot?

To learn a Bode plot, first establish the acquire, zero, pure frequency, and damping ratio of the system. Then, comply with the steps above to plot the magnitude and part curves.